Mge Pulsar Evolution 2200 Software Informer
Mge Pulsar Evolution 2200 Software Informer. Simply double-click the downloaded file to install it. Dvd Fab Passkey Torrent. UpdateStar Free and UpdateStar.
• Pulsar M 2200 RT 2U 2200 RT 3U 3000 RT 2U 3000 RT 3U 3000 RT 3U XL EXB RT 3U Installation and user manual - Page 1 34003641FR/AA. • - Page 2 34007776EN/AB. • Before installing Pulsar M, please read the booklet on the required safety instructions. Then follow the indications in this manual.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar M range, we invite you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative. • Introduction Pictograms Important instructions that must always be followed. Information, advice, help.
Visual indication. Audio signal. In the illustrations on the following pages, the symbols below are used: LED off LED on LED flashing - Page 4 34007776EN/AB.
• Presentation Standard positions. Download lagu dangdut ukts busmod. 6 Tower position. 6 Rack position. 6 Rear panels.
7 Pulsar M 2200 / 3000. 7 Pulsar M EXB (optional battery module). 7 Control panel. 7 Installation Unpacking and contents check.
8 Installation in tower position. 9 Installation in rack position. • Tower position Rack position - Page 6 34007776EN/AB Dimensions (H x W x D) in mm Pulsar M 2200 RT 2U 440 x 86 x 640 Pulsar M 2200 RT 3U 440 x 131 x 490 Pulsar M 3000 RT 2U. • 1.2 Rear panels Pulsar M 2200 / 3000 Pulsar M EXB (optional battery module) 1.3 Control panel 1. Presentation (1) USB communication port (2) RS232 communication port (3) Connector for automatic recognition of an additional battery module (4) Slot for optional communication card (5) Connector for remote ON/OFF and RPO (Remote Power Off) control (6) Connector for additional battery module.
Installation 2.1 Unpacking and contents check (30) Pulsar M 2200 or 3000 UPS (31) connection cable to AC-power source (32) 2 connection cables for the protected equipment (33) RS232 communications cable (34) USB communications cable (35) 2 systems to secure power plugs (36) Solution-Pac CD-ROM (37) Documentation Packing materials must be disposed of in compliance with all local regulations concerning waste. • It is advised to first install the battery module, then the power module above. Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by MGE UPS SYSTEMS. Installation - Page 9.
Installation 2.4 Communication ports Connection of RS232 or USB communication port (optional) The RS232 and USB communication ports cannot operate simultaneously. Installation of the communication cards (optional) - Page 6EN/AB 1 - Connect the RS232 (33) or USB (34) communication cable to the serial or USB port on the computer equipment. • 2.5 Connections with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connections with a HotSwap MBP module (optional) The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads (HotSwap function). Installation 1 - Connect the UPS socket (10) to the AC- power source using the cable (31) supplied. Installation HotSwap MBP-module operation UPS start-up with the HotSwap MBP module 1 - Check that the UPS is correctly connected to the HotSwap MBP module. 2 - Set switch (53) to the Normal position. 3 - Start the UPS by pressing the ON/OFF button (27) on the UPS control panel.
The load is supplied by the UPS. • If UPS personalisation is desired, it is advised to enter the personalisation mode at this time. This mode may be entered using the buttons on the control panel or the Personal Solution-Pac software (Windows) included on the Solution-Pac CD-ROM provided by MGE UPS SYSTEMS. 3.2 Operation on battery power. • Pulsar has the choice of two remote control options. ◗ RPO: Remote Power Off allows a remote contact to be used to disconnect all the equipment connected to the UPS from the power supply. Restarting the UPS requires manual intervention.
• Contact open: shut down of UPS Contact closed: start-up of UPS (UPS connected to the network and network energized) Note: local On/Off control via button (27) has priority over the remote control order. Contact open: shut down of UPS To return to normal operation, deactivate the external remote shut down contact and restart the UPS using button (27). Access to measurements and personalisation data 4.1 Display menus arrangement 4.2 Access to measurements Press the scroll button (25) to access any status conditions and alarms, then the measurements for voltage, current, frequency, power output and battery backup time. 4.3 Personalisation using the control panel Local personalisation Function. Access to measurements and personalisation data Output personalisation Function Output voltage Frequency converter Output frequency Transfer to the bypass AC input Overload level (1) These parameters may be modified only when the UPS is OFF.
Kala is thus the premier software for studying and practicing Classical Vedic Astrology. Download varahamihira astrology software for beginners. On a more modern note: Kala has the most accurate planetary calculations, thanks to the extremely accurate Swiss Ephemeris - which is an astrologically designed version of the most accurate NASA JPL ephemeris.
- пятница 15 марта
- 30